Brewing Beer with a Sous Vide Cooker



In beer brewing, the techniques that you use to extract the sugar that the yeast turns into alcohol are very important.  Sugar is pulled from malted grain by soaking it in hot water, which is called mashing.  The temperature of the water, and the length of time the grain is soaked makes a very big difference in the amount of sugar extracted.  The amount of sugar received is determined by measuring the density of the resulting water using a device called a hydrometer.  The ratio of extracted sugar compared with the theoretical maximum amount of sugar is called efficiency and is usually somewhere around 75%.

In addition to getting the sugar out of the grain, soaking the grain can have other effects by breaking down various proteins which can effect the flavor, the amount of head, and other factors in the resulting beer.  In order to get some of these secondary effects brewers can do multi-rest mashes where they soak the grains at different temperatures for different amount of time.  If you want more homebrewing theory, check out Palmer's excellent book.

All of this is difficult to do in the real world when all you are armed with is a stove with a knob that, when turned, will eventually change the temperature of the 5 or more gallons of water and grain.  Basically, it turns into doing a kind of human-powered PID controller, which is no fun at all.

Being an engineer, I thought that this definitely falls under the category of a task that a computer could do better than a human.  I started doing some planning in my head about what would be required for some kind of computing device to control my stove (or other heating element) so that I could set an exact temperature and let the computer worry about keeping the beer at the temperature.  It turns out that it's not hard since this kind of temperature control is used in industry all the time for many purposes besides mashing beer.

The auto mash temp control project was sitting solidly on the back burner in my brain when I saw that Sous Vide cookers were getting cheaper.  I will spare you the details, but Sous Vide cooking is a method of cooking by putting food in a water bath that is kept at an exact temperature by a temperature controller.

If you replace the water with wort (unfermented beer) then this sounds exactly like what I wanted to control mash temperature.  Sous Vide cookers operate in the same temperature range as typical mash temperatures, are generally made from food-safe materials, and are made to attach to the sides of standard cooking pots. All of these qualities make them ideal for use with a mash.

So I bought an Anova Sous Vide cooker and made a batch of beer, and the results were excellent.  I made this Irish Dry Stout recipe, with a mash temperature of 152 degrees F for 90 minutes, and a 170 deg mash out for 10 minutes.  In the end I got 75% efficiency, and I pretty much sat back and relaxed during the mash step instead of a typical batch where I have to watch the temperature like a hawk the whole time.

Footage of the mash and details and tips for using the Anova cooker with a mash are in the the video above, but the big takeaways are:
  1. The Anova cooker seems to work quite well for mashing, and I will definitely use it again.
  2. Only use the cooker for fine-tuning the mash temperature.  For brute force heating use your stove burner.  This is to avoid caramelizing any sugars to the Anova's heating cool which would make the Anova hard to clean and may effect the flavor of the beer.
  3. Use a grain bag.  This keeps the grain from plugging up the innards of the Anova.  Be careful about where you aim the output of the Anova's circulator such that the grain bad doesn't get pulled into the Anova's intakes.
  4. Carefully calculate batch size.  The liquid level must fall within the Min and Max lines on the Anova and this can be tricky to hit correctly when using a large brew pot, so do your math ahead of time to get it right.
Disclaimer: I don't know if Anova recommends using their Sous Vide cooker in this way, so I can't be responsible for any damage to the Anova cooker, problems with the resulting beer, or any other issues or problems you might encounter.

Sunday, February 03, 2013

Scale results, round 2

I made a second run on my scale tester.  This time I used a 10KOhm thermistor as my temperature sensor.  This gave me around 0.15 degrees (F) of resolution, compared with the 1 degree resolution of the previous temperature sensor I used for the last test run.



Figure 1: Weight and Temperature vs. Time

The first graph this time is the usual weight and temperature over time.  You can see that the weight and temperature appear to be highly correlated just like the first test run. The other thing is that the temperature appears much less noisy then in the previous run.

Figure 2: Nominal weight minus weight vs. Average temperature
In Figure 2, I graphed the delta in weight vs nominal against a moving average of temperature.  I also threw down a best-fit linear trend line.  I can immediately see that the point cloud is much tighter than in the previous test run, which seems good.

Figure 3: Adjusted weight

The last graph is a plot of the weight reading adjusted by the trend line equation from Figure 2.  The ideal line is a straight line at 55 lb. Clearly the line is not straight but it certainly improves the data.  The weight reading varies by +/- 0.2 lb instead of +/- 0.75 lb for the unadjusted weight readings.

Conclusions

The adjusted weight did not seem much different from the previous test run, but it still seems useful.  I think I can now go on to implement the data logger for this project which will convert weight and temperature sensor readings to specific gravity.

There are still some unknowns here.  One is that the test runs have only been run on a constant 55 lb test weight.  It's certainly possible that the numbers will change if a different weight is used.  It might be worth re-testing with weights of 45, 65, and 75 lb weights.

Additionally, there seems to sometimes be a lag between temperature changes and weight changes.  This could be attributable to the temperature sensor and scale having different thermal mass, which is almost certainly true.  I could account for this by attaching the temperature sensor to the scale with thermal paste to ensure that they are at relatively the same temperature.

Tuesday, January 22, 2013

First scale test results

I took some time to analyze the results from my scale test.  If you like graphs, then keep reading.  If you don't like graphs then skip to my conclusion at the bottom.  I happen to like graphs...

To summarize the previous post, I wanted to see if there were two effects happening to my fancy new RS232 scale: 1) temperature and 2) sensor drift (or creep).  The easiest way to track this was to measure the weight of an object with a constant mass over time, while also measuring temperature over the same time span.  I did that and now have a week's worth of measurement data to sift through.

Figure 1: Temperature and Weight vs. Time
First I graphed weight and temperature each versus time.  Figure 1 shows this graph.  You can immediately see that the measured weight correlates closely with the temperature, so clearly I was right that there is a temperature effect.  The second thing to note is that the weight line shows clear quantization, but this is to be expected as the scale only specifies to have a 0.1 lb resolution (but it's still nice to see it clearly in the graph).  Another thing to note is that the temperature is pretty noisy.
Figure 2: Average Temperature and Weight vs. Time
Figure 2 is the same graph but with a moving averaged temperature.  Perhaps a "moving average" is not the correct term for this; I never did much with formal statistics.  I basically just calculated each reading by taking the mean of the previous 6 readings.  You can see the temperature line looks much less noisy now and the correlation between temperature and weight still remains.

Figure 3
My next task was to try and figure out the mathematical relationship between weight and temperature, so that I can then (hopefully) correct for temperature and get a more accurate weight reading.  The graph for weight versus temperature is shown in Figure 3.  There are several interesting things here.  The first is that you can see that both the weight and the temperature are quantized since all the blue points in the graph come out on grid lines.  The next thing to note is that the point cloud is pretty widely distributed (which isn't good).  I had Excel generate a best fit linear trend line.
Figure 4
Next up I repeated that graph (Figure 4) but with the the averaged temperature data from Figure 2.  Now you can see that the quantization in the temperature data has disappeared but remains for the weight, which is what we'd expect.  The trend line has changed a little based on this adjustment.  I also threw a 6th order polynomial fit trend line on the data to see if that would fit the data better, but as you can see that is nearly a straight line, so we'll stick with the linear fit line for future calculations since it seems to be a pretty good approximation (at least compared with a polynomial fit).
Figure 5
Now from this we can use the calculated trend line to create a mathematical attempt at canceling out the temperature effect of the scale readings.  Figure 5 is a graph of the temperature-adjusted weight plotted over time.  The ideal line would be a line that is constant at 55 lb.  The adjusted weight line is clearly not a straight line but if you compare it to Figure 2 we have certainly made an improvement over the raw weight readings.

As it stands this temperature correction is probably useful enough that I could start using the scale for continuous weight measurements, however I'd like to make it better if I can.  I think one improvement I can make (which I mentioned in my previous post) was that my temperature sensor has pretty low resolution (about 1 degree Fahrenheit). I suspect that having a sensor with 0.1 degree resolution would help, and might bring the point cloud in Figure 3 into a tighter cloud which would make the generated trend line more accurate.  So now I'm going to start looking around for a more suitable temperature sensor (I might already have one on hand in my parts library) and re-run the test to gather fresh data.

Wednesday, January 09, 2013

Testing an RS232 scale

To further the experiments I've been doing with measuring specific gravity, I needed to take long-term continuous weight measurements (5-10 days total). I started searching for a scale or load cell that would be appropriate.
My specific use case involves monitoring the weight of an object in the range of 50-70 lbs for 2 weeks.  Since we have a heavy weight on the scale for a long time a problem that could come up is sensor drift (also sometimes called creep).  This effect is similar to what happens if you hang an object from a suspended spring.  Over time the spring will slowly deform.  The rate of the deformation depends on many factors like the weight of the object and the physical properties of the spring.  The same thing happens with a scale.  Although mechanically different from a suspended spring, in many other ways it's very much like a spring.

Another factor that can throw off the readings from a scale is temperature.  As the temperature changes the properties of the components in the scale also change.  If these changes aren't compensated for in some fashion then they will affect the scale's readings.

I initially tried to measure a 55 lb test weight using a 75 lb maximum capacity digital scale.  Within minutes the scale's readings started drifting.  I assumed that this was probably due to creep and was probably so prominent because I was weighing something close to the rated capacity of the scale.  This scale also had the additional failing that it did not have a way to communicate externally (which as you'll see soon was an important requirement) so I decided to look for a different scale.

I reasoned that if I found a scale that had a maximum capacity that was significantly larger than object I was weighing, then it might not display significant effect from creep (or at least for the 2 week period that I needed continuous readings).


Luckily I found a 300 lb capacity shipping scale (MyWeigh HD-300), and a well-written tutorial from Adafruit.  This scale was a little more expensive than what I had in mind, but it's worth the price considering all of its features:
  • 300 lb capacity
  • RS232 communication
  • ability to disable auto-off (most scales turn off automatically which sucks for continuous measurements)
I quickly started an "eyeball" test by again placing my 55 lb weight on the new scale.  I kept a log book near the scale and roughly every 60 minutes I would write down the time and the displayed weight.  I left this experiment running for about 4 days.  I should note that I didn't stick to the 60 minute test interval that closely.  Sometimes I would leave several hours between readings, sometimes it was more like 30 minutes, and I didn't wake up to take readings in the middle of the night; I like science but I like sleep more.

The results of this test told me that something was causing the displayed weight to vary by about 1 lb over the course of 4 days.  I had a suspicion that temperature was causing much of the variation (the weight would be lower when it was cooler in my house and higher when the temperature was higher).  I couldn't really tell if there was any effect from sensor creep.

Next I decided to repeat the above experiment but make it a little more scientific.  For this run I wanted to run for at least 10 days and gather temperature and weight readings every 10 minutes.  Of course, this is exactly what computers are made for.

The test set up consists of a python script running on an old laptop.  The script communicates with the scale via its RS232 interface to gather weight readings.  To get the temperature I decided to use an Analog Devices TMP36 sensor that I already had on hand.  Coincidentally, Adafruit had another tutorial on using this sensor with an Arduino.  I used some of the ideas from the tutorial but wrote my own Arduino firmware to make it act as a serial thermometer.

The test script on the laptop was modified to also query the Arduino for the temperature and log the returned value along with the measured weight value to a file every ten minutes.  

The test setup from left to right: laptop power supply, USB wifi dongle, scale control box, laptop, plywood to act as stable platform for scale, Arduino with TMP36 sensor, MyWeigh HD-300 scale with 55 lb test weights
I put the source code for the python test script and the Arduino firmware on github.  Keep in mind that the script was written to run on Windows and would need to be ported to run on another operating system.  Also, since I implemented the script very quickly I didn't spend much time or effort on error checking so it's not very robust in that respect.  You have been warned.


At this point you may be wondering why I didn't just use the Arduino by itself to do the data logging.  I have a few reason for that:
  • I needed a circuit to convert the RS232 voltage levels of the scale to TTL voltages that the Arduino can understand.  I already had the hardware to do that but I didn't want to waste time assembling it when I had a laptop with a perfectly good RS232 port available.
  • I didn't have an Real-Time clock to keep track of time or anything to use for large data storage (SD card socket).  The Adafruit data logging shield would have been ideal for this but I didn't want to wait to run the test.
After I was half way through implementing the test I realized that the TMP36 sensor used in combination with the Arduino's 10-bit resolution ADC only gives a resolution of about 1 degree Fahrenheit.  I would have preferred to have 0.1 degree of resolution but decided to run the experiment anyway and see how the numbers looked.

I'll create an additional post with the results from the first test run.

Tuesday, January 08, 2013

Beer Crate

Over the holidays, I set out to build some more permanent storage cases for my homebrew beer.  I had just been using whatever cardboard beer boxes I could get my hands on.  Now that I'm getting more into homebrewing I thought it would be nice to put my woodworking skills to good use.

The finished beer crate
Design
Design decisions:
  • Be easily stackable (up to 3 or 4 high)
  • Some sort of locking/registration mechanism so when they're stacked they stay stacked
  • Separators between bottles so the bottles don't knock together when moved
  • Sturdy!
  • Some method of identifying what beer is in a given case
  • Hold at least 12 bottles (24 seems like too much)
  • Tall enough to hold any normal 12 ounce beer bottle
  • Handles for ease of carrying
I started by measuring a cardboard beer box to get some general size guidelines.  I also measured the tallest 12 ounce beer bottle I could find to see what the height needed to be.

Based on the measurements I designed the beer crate in Sketchup (as usual).  I decided to use 3/4 inch pine boards for the sides and end pieces and 1/8 inch hardboard for the bottom and the separator pieces.  There are two interesting features: The first is that I plan on applying chalkboard paint to the sides of the crate so I can write info on the batch in chalk.  The second interesting feature is a trick I learned from woodgears.ca.  The idea is to use marbles to "lock two flat surfaces together in a removable fashion.  The idea is to drill two hols on the two surfaces just wide enough and deep enough to fit a marble.  The marble then sits above the surface of the top edge end piece and fits into a matching hole on the bottom of the end piece.  In this way the crates can be stacked without worrying about them slipping.  Since the marble is spherical it's easier to line up than a cylindrical peg.


The beer crate design in Sketchup
Construction
The construction details are not that interesting since they are just standard woodworking techniques.  The sides, ends, bottom, and separator pieces were cut to size from pine boards and hardboard sheets.  A slot was cut into the sides and end pieces to fit the bottom piece similar to the way drawer bottoms are traditionally made.  

The hand holds were cut in the end pieces with a forstner bit and a jigsaw, and sanded smooth using an oscillating spindle sander.  The recesses for the marbles were drilled using a drill press and a template I made  to make sure the holes line up properly.
Slots were cut halfway through the separator pieces so that they would fit together.  To make these cuts I used my table saw and just stacked up several separators at a time and pushed them into the saw blade until the blade hit a pencil mark half way through the separator.  There are cleaner ways to make this cut but since the cut is not visible after the seperators are assembled, I wasn't too concerned with cosmetics.  If you'd like to see how these separators work just take a look at a carboard 12 pack box and they go together the same way; they're just made of hardboard instead of cardboard.

I just used a butt joint to connect the side and end pieces.  I put 1.25" wood screws into countersunk pilot holes to hold it.

Finish
I first sanded all the pine pieces mainly to get rid of machine marks.

I used two coats of clear gloss wipe-on polyurethane to seal the side and end pieces.  I didn't put any stain on the wood because I like the look of unstained pine.  I left the outside face of the side pieces unsealed since I wanted to apply the chalkboard paint there.

For the chalkboard surfaces, I first primed with some white latex paint that I had lying around.  After that had dried I sanded lightly and applied one thick coat of black Rustoleum chalkboard paint using a foam brush.  After it had dried it didn't seem to need a second coat so I left it at that.

Future Improvements
This was the first project that didn't require me to make some adjustments to the design during construction.  I credit using Sketchup and doing careful measurements before I started.

Now that I've finished the prototype I need to make 8 or 9 more to hold all of my homebrew beer.  I'm really looking forward to doing some "assembly line" style woodworking.  It seems like 90% of the time in woodworking is spent setting up for each cut, so making 10 of something doesn't take 10x more time than making 1.  I usually only make 1 of a project so it will be fun to make many more.

Even though this project went well I have some concerns and improvements for the future:
  1. I might want to use some nicer wood like oak in the future.  Then again the pine looks pretty good and has the additional advantage of being cheap.
  2. The butt joint isn't that pretty; using dovetails or finger joints would look better.
  3. I'm a little worried that the placement of the marbles may be a little too precise and I might have trouble getting things to line up when I have multiple beer crates.  I can probably get around this by only using two marbles placed above each handle instead of the current 4 marble design.  Also I could make a jig to align the pieces when I drill the pilot holes for the screws.  The jig would ensure that I get the distance between the end pieces exactly the same every time.


Friday, June 04, 2010

I did some more work on pressure sensor testing, this time with a MP3V5004 sensor which has higher accuracy than the MPX5010. This sensor definitely did work better than the MPX5010, but it still was not accurate enough for my purposes. I also leanred that my test rig was very sensitive to two things: 1) The position of the tubes (even if one of them moved 1/64th of an inch it would affect the readings significantly), and 2) if there was liquid already in the tube from a previous reading. To correct this I secured the rig's test tubes so they couldn't move at all and I made sure to clear any liquid out of the tubes between readings. With these changes I got much higher accuracy, but the sensors I tested were still not accurate enough.

I found another pressure sensor made by Honeywell (HSCSAAN001PDAA5) that has significantly higher accuracy, but it is also MUCH more expensive ($40-50 per sensor). So I'm going to try some other specific gravity measurement ideas before I invest money in the pricey new pressure sensor.

Lately I've been experimenting with counting CO2 bubbles produced by a fermentation as an indirect way of measuring specific gravity. Currently I'm using a method which shines an infrared beam through an air lock. When a certain amount of CO2 has been produced in the reaction chamber a CO2 bubble goes through the liquid contained in the air lock (which really just acts as a one-way valve). When this bubble escapes it breaks the infrared beam momentarily which I can then detect electronically.

So far I've proven that I can detect bubbles with this apparatus; now I need to make sure that I can detect close to 100% of the escaping bubbles. Here are some pictures of my current test setup:




















Tuesday, April 13, 2010

I was able to find some sufficiently small hose clamps that fixed my air leakage problems, but now I'm having trouble with the accuracy of the pressure sensor. Here is some of the data I got during my last test session:

SG test solution -> ADC counts (0-1023)
1.000 -> 220
1.100 -> 240
1.062 -> 237
1.028 -> 233
1.000 -> 227
1.100 -> 244
1.062 -> 237
1.100 -> 242
1.000 -> 223
1.000 -> 226

So as you can see the trend is generally correct but there is too much hysteresis in the values. After perusing the datasheet for the sensor it seems that the overall accuracy is +/- 5% worst-case, so the sensor is performing much better than its spec. But it's still not very useful for my purposes.

Tuesday, April 06, 2010

I've been working with the pressure sensor again. I finally got a very ugly prototype of a hand-held meter built. The basic idea is that I have the pressure sensor wired to one of the analog inputs of an arduino, and then the arduino sends sample data out via serial to my PC.

I got some pretty good readings that look like I'll have a resolution of around 0.005 SG (which is usable, I think). The only major problem I ran into was that air was slowly leaking out the tubes that were in the water, which means the seal I have between the tubes and the pressure sensor ports isn't good enough. So the next thing on my list is to come up with a way to seal the tubes better.

Here are some pictures of the prototype:
















Tuesday, January 05, 2010

I've been continuing to experiment with the pressure sensor from the previous post. I had a problem for a while where the pressure sensor results were varying by +/- 50mV which basically made the pressure sensor unusable for my purposes as I was looking for better than 5mV accuracy. I did some more troubleshooting and discovered that my power supply was causing the variance. I put an additional voltage regulator before the circuit and that brought the accuracy down to 1-2mV, which is much more usable.

I've also found another Freescale pressure sensor (MP3V5004G) that has about double the accuracy of the sensor I'm currently using (MPX5010). I'm going to try out that sensor in the near future to see if it improves my results.

Now that I'm getting decent results I'm going to build a prototype meter using an arduino and start experimenting with a bit of software filtering and averaging to see if I can get a more accurate result. Eventually I'll also attach an LCD display to the arduino and make a hand-held meter for measuring specific gravity.

Here are some of my latest experimental results with the MPX5010 and solutions of varying density:

hydrometer reading of solution -> sensor reading
(with h = 6 inches)
1.000 -> 882mV
1.028 -> 896 mV
1.062 -> 933mV
1.100 -> 961 mV

(with h = 8 inches)
1.000 -> 1.105V
1.028 -> 1.130V
1.062 -> 1.148V
1.100 -> 1.177V

Tuesday, October 06, 2009

I had a little time to experiment with a new project. I'm working on using a Freescale pressure sensor to measure the specific gravity of a liquid. This is a piece of a larger project that I'm working on, but I need to research this before I work on the rest of it. More on that later.

Pressure in a liquid follows this formula:
p = ghd
where p = pressure, h = height of liquid above sensor, g = acceleration of gravity, d = density of liquid

So using a differential pressure sensor (MPVX5010DP) from Freescale, I can get all of the values in the formula and solve for d. The physical test setup is show in the picture below. Basically I have lengths of plastic tubing of two different lengths attached to the sensor's pressure ports (make sure to get the right tube to the right pressure port; pressure port 1 always have to have a higher pressure on it than pressure port 2; check the datasheet). The tubes are then tied to a steel ruler with the tube ends a fixed distance apart (in this case 4" apart).

It seems like the pressure reading does indeed change with the density of the liquid the probe is placed in. However the difference in the readings is fairly small. This tells me a couple of things:
1) I should increase the distance between the end of the tubes (essentially increasing "h" from the formula before). This should increase the magnitude of the voltage read from the sensor, thereby amplifying the sensor voltage. Eight inches between the tube ends should be good. 2) Since I'm eventually going to be reading the sensor voltage using a microprocessor's ADC, I can decrease the voltage range of the ADC to increase the resolution of the ADC readings. Based on my final application, I'm going to set the voltage range to 0-1.1 V.

Here is then data I got with several different sugar solutions:

Hydrometer Reading -> Sensor Reading
1.000 -> 707mV
1.036 -> 723mV
1.068 -> 734mV